MIRUS Neutral Current Eliminator (NCE) 
  • Eliminates the need for doable ampacity neutrals upstream
  • Prevents voltage flat-topping caused by non-linear loads
  • Restores ride-through capability of computer equipment

Product Details

MIRUS Neutral Current Eliminator (NCE)

A 3-phase, low zero sequence impedance autotransformer, which when connected near to and in parallel with the harmonic generating non-linear loads (usually connected at the distribution panel), provides an alternate path for 3rd, 9th, & 15th current harmonics (triplens) which the loads create. Patented Field Adjustable Impedance (FAI) feature allows for adjustment of NCEâ„¢ zero sequence impedance to field conditions.

Reduces neutral current and neutral-to-ground voltage as well as both current and voltage triplen harmonic distortion.

Features

• Diverts the flow of harmonic currents away from neutral and upstream transformer
• Reduces high neutral current and neutral-to-ground voltage
• Eliminates the need for doable ampacity neutrals upstream
• Reduces losses and lowers operating temperature in upstream distribution transformer
• Substantially reduces primary winding circulating currents in distribution transformers
• Reduces current distortion at UPS, generator or Utility service
• Saves energy by reducing harmonic losses
• Prevents voltage flat-topping caused by non-linear loads
• Lowers voltage distortion to prevent premature equipment failure
• Restores ride-through capability of computer equipment
• Improves Power Factor
• Integrated ammeter measures neutral current removed

MIRUS Harmony-3E Isolation Transformers and Auto Transformers HARMONYâ„¢ SERIES isolation transformers and autotransformers combine very low zero sequence impedance outputs with phase shift...
MIRUS 5-13 Neutral Current Eliminator 3-phase, 3-wire autotransformers with 30°, 15° or 20° phase shift between input and output. They are connected in series with the supply to variable ...
MIRUS Drive 12/24 Transformers Multiple output auto or isolation transformers ideally suited for reduction of harmonics generated by VFDs or other 3-phase rectifier loads. Drive 12/24â„¢...
MIRUS SOLV Harmonic Analysis Software SOLVâ„¢ is a powerful simulation program that will calculate current and voltage distortion levels by simulating the Mirus Lineatorâ„¢ and Variable Speed...
MIRUS Onics Harmonic Mitigating Remote Panelboard Up to 4 Circuit Breaker panelboards with built-in passive harmonic filtering. Eliminates the need for K-rated transformers and double ...