MEGGER Battery Ground Fault Tracer 
  • Wide fault resistance measurement range from 1 kO to 399 kO & Immune to distributed noise
  • Soft-start charging system to prevent sensitive relay tripping & Convenient, hand-held receiver
  • Simplifies fault tracing by identifying fault characteristic magnitudes

Product Details

MEGGER Battery Ground Fault Tracer

Ground faults in ungrounded dc battery systems easily located. Operates in high electrical noise environment. Simplifies fault tracing by identifying fault characteristic (resistive and capacitive) magnitudes.

The Battery Ground-Fault Tracer is an economical, manually-balanced instrument that identifies, tracks and locates ground faults in ungrounded dc battery systems - on-line. It is particularly effective in a high electrical noise environments, as the strength of the test current can be adjusted.

The Battery Ground-Fault Tracer accelerates fault location by eliminating trial-and-error procedures and because faults can be located without going off-line. It is particularly useful in any industry where supply of power for operating measurement, communication and control equipment is critical.

Product Description

Megger Battery Ground Fault Tracer has Wide fault resistance measurement range from 1 kO to 399 kO and Immune to distributed noise with soft-start charging system to prevent sensitive relay tripping and Convenient, hand-held receiver. This test instrument simplifies fault tracing by identifying fault characteristic magnitudes.

FLUKE 1550C/Kit Insulation Resistance Testers The new 1555 and redesigned Fluke 1550C insulation resistance testers, offer digital insulation testing up to 10kV, making them ideal for tes...
MEGGER CB101 Calibration Box 5 kV Gives quick check of insulation tester calibration, Contains high quality resistors, Calibration certificate provided The CB101 is a calibration box s...
MEGGER MIT510/2 Insulation Resistance Tester 5 kV CAT IV 600 V, Mains or battery powered, Digital/Analogue backlit display, Selectable test voltage from 250 to 5000 V, Automatic IR test, ...
MEGGER S1-5005 Insulation Tester 5 kV Insulation resistance measurement to 15 TO, Mains and battery powered testing, Three alarms and three timers, USB and RS232 output, Data storage, Bac...
MEGGER S1-5001 Insulation Tester 5 kV Polarisation index, PI, and dielectric absorption ratio, DAR, Step voltage, SV, and dielectric discharge, DD, Insulation resistance measurement to 15...