Free Call Australia : 1 800 834 991

Related Products

HIOKI PW3360 Clamp On Power Logger

HIOKI PW3360 Clamp On Power Logger New
  • 3 circuits (1P2W) or single circuit (1P3W, 3P3W, 3P4W), 50/60 Hz
  • Clamp input
  • Harmonic analysis

Product Details

HIOKI PW3360 Clamp On Power Logger are multi-channel power measuring devices utilizing clamp sensor input to accurately and safely measure power on single-phase to three-phase lines. The PW3360 compact 3-Phase 4-Wire energy loggers monitor power demand and other power parameters to aid in energy audits and validate energy saving measures.

Key Features
• Supports single to three-phase, 4-wire circuits
• Measure between 90V to 780V
• Simultaneously measure up to three single-phase, 2-wire circuits (in the same power system)
• Slim, compact design that can be placed anywhere
• Store months of data on SD cards
• The QUICK SET function guides you in making the right connections
• Choose PW3360-21 for harmonic measurements up to the 40th order

Basic Specifications
Measurement line & number of circuits : 50/60 Hz, Single phase 2 wires (1/2/3 circuits), Single phase 3 wires (1 circuit), Three phases 3 wires (1 circuit), Three phases 4 wires (1 circuit), Current only: 1 to 3 channels

Measurement items : Voltage RMS, current RMS, voltage fundamental wave value, current fundamental wave value, voltage fundamental wave phase angle, current fundamental wave phase angle, frequency (U1), voltage waveform peak (absolute value), current waveform peak (absolute value), active power, reactive power (with lag/lead display), apparent power, power factor (with lag/lead display) or displacement power factor (with lag/lead display), active energy (consumption, regeneration), reactive energy (lag, lead), energy cost display, active power demand quantity (consumption, regeneration), reactive power demand quantity (lag, lead), active power demand value (consumption, regeneration), reactive power demand value (lag, lead), power factor demand, pulse input
[PW3360-21 only]: Harmonic voltage level, harmonic current level, harmonic power level, content percentage, phase angle, total harmonic distortion (THD-F or THD-R), up to 40th order

Voltage ranges : 600 V AC (Effective measurement range: 90.00 V to 780.00 V)

Current ranges : 500.00 mA to 5.0000 kA AC (depends on current sensor in use),
50.000 mA to 5.0000 A AC (Leak clamp on sensor only)

Power ranges : 300.00 W to 9.0000 MW (depends on voltage/current combination and measured line type)

Basic accuracy : Voltage : ±0.3% rdg. ±0.1% f.s
Current : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy
Active power : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy (at power factor = 1)

Display update rate : 0.5 sec (except when accessing SD card or internal memory, or during LAN/USB communication)

Save destination : SD memory card, or internal memory at real time

Data save interval : 1 sec to 30 sec, 1 minute to 60 minutes, 14 selections

Save items : Measurement value save: Average only / Average, Maximum, Minimum value
[PW3360-21 only]: Harmonic data save: Average only / average, maximum, minimum value in binary format
Screen copy: BMP form (saved every 5 min. at minimum interval time)
Waveform save: Binary waveform data

Interfaces : SD memory card
HTTP server function, Remote settings by communication program, or data downloads
USB 2.0: When connected to a PC, the SD card and internal memory are recognized as removable storage devices, Remote settings by communication program, or data downloads
Pulse output: proportional to active power consumption when measuring integral power consumption, Isolated open-collector signal

Functions : Connection check, Quick Set navigation guide, clock, pulse input

Power supply : AC Adapter Z1006: (100 to 240 V AC, 50/60 Hz), 40 VA (including AC adapter)
Battery Pack 9459: (DC 7.2 V, 3 VA, charging time 6 hr 10 m), 8 hours of continuous use (with back light off)

Dimensions and mass : 180 mm (7.09 in) W × 100 mm (3.94 in) H × 48 mm (1.89 in) D, 550 g (19.4 oz) without PW9002
180 mm (7.09 in) W × 100 mm (3.94 in) H × 67.2 mm (2.65 in) D, 830 g (29.3 oz) with PW9002

Accessories : Voltage Cord L9438-53 × 1 set, AC Adapter Z1006 × 1, USB cable × 1, Instruction manual × 1, Measurement guide × 1, Color spiral tubes × 1 set: red, yellow, blue/two each, for color-coding clamp sensors, Spiral tubes for grouping clamp sensor cords × 5

Product Description

HIOKI PW3360 Clamp On Power Logger is a portable power loggers for energy audits and energy conservation.The PW3360 compact 3-Phase 4-Wire energy loggers monitor power demand and other power parameters to aid in energy audits and validate energy saving measures.

ELSPEC G3500 BLACKBOX Portable Power Quality Analyzer. Built on the same innovative technology as the BLACKBOX fixed Power Quality Meter (PQA), the ELSPEC G3500 BLACKBOX Portable Digital Pow...
HIOKI 3169 Clamp On Power HiTester portable power meters and analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision...
HIOKI 3193 Power HiTester DC, or 0.5 Hz to 1 MHz wide band width, Wide spectrum power meter for comprehensive device assessment A rich assortment of measurement functions including volta...
HIOKI 3196 Power Quality Analyzer Monitor and record the quality of power to analyze the cause of trouble when it occurs! HIOKI 3196 Power Quality Analyzer is your most reliable and compl...
METREL MI 2092 Power Harmonics Analyser Three phase, multifunction power quality analyzer suitable for performing all the most frequent measurements and diagnostics in different electrica...