Free Call Australia : 1 800 834 991

Related Products

Hioki 3290-10 Clamp On AC/DC HiTester

HIOKI 3290-10 Clamp On AC/DC HiTester 
  • Polarities independently (±peak value of waveform, in DC mode)
  • Current waveform or true RMS value (2 V / setting range)
  • Current integral value (1 VDC / setting range)

Product Details

HIOKI 3290-10 Clamp On AC/DC HiTester All the Functions You Need for Measurement at DC or 1Hz and Up

Choice of three sensors (Example combinations)
3290/3290-10 +9691 : Measure up to 100A
3290/3290-10 +9692 : Measure up to 200A
3290/3290-10 +9693 : Measure up to 2000A

Choice of measurement methods
DC (for battery measurement)
AC+DC RMS (for full-/half-wave rectification measurement)
AC RMS (for current distortion measurement)
PEAK (for peak value measurement) of inrush current, etc.)

Choice of output (Simultaneous output)
Effective value output, frequency output, waveform output

3290-10 Functions
Current integral measurement
(obtain polarity-specific integrated DC values)
Operating time/duty measurement

Measurement method : DC, AC+DC (True RMS), AC (True RMS)

Peak value display : Polarities independently (±peak value of waveform, in DC mode)

Separate AC from DC output : None

Output (terminal 1) : Current waveform or true RMS value (2 V / setting range)

Output (terminal 2) : Current integral value (1 VDC / setting range)

Integral current measurement : ±, +, - integral, average value

Rate measurement : Operating time rate, total measurement time

Timer settings : 99 hr, 59 min. (for repeated up to 20 times)

Data storage : Peak, integral value, operating time rate, or other

Basic accuracy at DC current : 20.00/ 100.0A (using the 9691 sensor): ±1.3 % rdg. ±0.10 A/ ±0.5 A
20.00/ 200.0A (using the 9692 sensor): ±1.3 % rdg. ±0.10 A/ ±0.5 A
200.0/ 2000A (using the 9693 sensor): ±1.8 % rdg. ±1.0 A/ ±5 A

Basic accuracy at AC current
(45 to 66 Hz) 20.00/ 100.0A (using the 9691 sensor): ±1.3 % rdg. ±0.08 A/ ±0.3 A
20.00/ 200.0A (using the 9692 sensor): ±1.3 % rdg. ±0.08 A/ ±0.3 A
200.0/ 2000A (using the 9693 sensor): ±1.3 % rdg. ±0.8 A/ ±3 A

Voltage measurement : None

Frequency measurement : 1.00Hz to 1000Hz, Basic accuracy: ±0.3% rdg. ±1dgt.

Crest factor : 2.5 or later, or rated peak value of sensor

Frequency characteristic : DC, or 1 Hz to 1 kHz (accuracy guaranteed range)

At monitor output: based on the using sensor

Other functions : Selectable of responce time, filter (fc=550 Hz)

Power supply : LR6 (AA) alkaline batteries × 4, Continuous use : 22 hr, or AC adapter 9445-02/-03 (The 3290-10 only: external power supply possible)

Dimensions, mass 155 mm (6.10 in) W × 98 mm (3.86 in) H × 47 mm (1.85 in) D, 545 g (19.2 oz)

Supplied accessories : Carrying strap ×1, LR6 (AA) alkaline batteries × 4

HIOKI 3290 Clamp-On AC/DC HiTester All the Functions You Need for Measurement at DC or 1Hz and Up Choice of three sensors (Example combinations) 3290/3290-10 +9691 : Measure up to 100A ...
HIOKI 3285 Clamp-On AC/DC HiTester AC/DC current measuring up to 2000 A Analog output for current measuring level, current measuring waveform, or frequency measuring level. The peak hold ...
HIOKI 3284 Clamp-On AC/DC HiTester Analysis for DC to distorted waves Analog output for current measuring level, current measuring waveform, or frequency measuring level. The peak hold fu...
HIOKI 3288 Clamp-On AC/DC HiTester Compact & easy, one-touch maintenance on all types of AC/DC equipment Model 3288-20: True RMS Use the 3288 for high current measurements such as UPS eme...
FLUKE 375 True-rms AC/DC Clamp Meter With true-rms ac voltage and current measurements, the Fluke 375 Clamp Meter can read up to 600 V and 600 A in both ac and dc modes, and is capable of...
AUD $ 740.00 ex GST