HIOKI 3169 Clamp On Power HiTester portable power meters and analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The 3169 is clamp on power meters designed to measure demand and harmonics, which are important for energy management, as well as basic electrical parameters such as voltage, current, power, power factor, and integrated power (watthours).
Key Features
• Simultaneously measure demand and harmonic waveforms that share the same voltage line over 4-circuits
• Data can be saved onto a PC card
• High-speed and continuous processing to measure individual waveforms
• High-speed D/A output for analog graph recording (Model 3169-21)
Basic Specifications
Measurement line & number of circuits : Single-phase 2-wires (4 circuits), Single-phase 3-wires (2 circuits), Three-phases 3-wires (2 or 1 circuit), and Three-phases 4-wires (1 circuit)
Note: 50 or 60 Hz, and that share the same voltage line
Measurement items : Voltage, Current, Active/ reactive/ apparent power, Active/ reactive power integration, Power factor, Frequency, Harmonic waveform value (up to 40th order)
Measurement range : [Voltage] 150.00 V to 600.00 V AC, 3 ranges, [Current] 500.00 mA to 5.0000 kA AC (depends on current sensor in use), [Power] 75.000 W to 900.00 kW (depends on combination of voltage, current range, and measurement line)
Basic accuracy : AC Voltage: ±0.2 % rdg. ±0.1 % f.s.
AC Current: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy
Active power: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy (at power factor = 1)
Clamp on sensor 9661: ±0.3 % rdg. ±0.01 % f.s. (different from each sensor models)
Measurement method : Digital sampling, PLL synchronization or 50/60 Hz fixed clock
Display refresh rate : 2 times /sec (except when a PC card accessing, or RS-232C communications)
Data save interval : Standard interval: 1 sec to 30 sec, 1 minute to 60 minutes, 13 selects
Fast interval: A single waveform, or 0.1, 0.2, or 0.5 sec (at instant value only)
Frequency characteristics : Fundamental waveforms up to the 50th order ±3% f.s. + measurement accuracy (of a 45 to 66 Hz fundamental waveform)
Other functions : Error connect check, language selection, display hold, setting backup, power shut off management, key lock, [3169-21 only] D/A output 4 channels, (±5 V DC f.s.)
Power supply : 100 to 240 V AC, 50/60 Hz, 30 VA max.
Dimensions and mass : 210 mm (8.27 in)W × 160 mm (6.30 in)H × 60 mm (2.36 in)D, 1.2 kg (42.3 oz)
Accessories : Voltage cord L9438-53 ×1 (Black/ Red/ Yellow/ Blue, 3 m (9.84 ft) length, Alligator clip ×4), Power cord ×1, Instruction manual ×1, Quick start manual ×1, CD-R ×1 (RS-232C interface operating manual) ×1, Input cord label ×1, Connection cable 9441 ×1 (for the 3169-21 only)