HIOKI 2104 Meter Relay 
  • 1 channel analog scale
  • Electronic design assures high accuracy and reliability
  • ±1.5% class
  • 100 mm (3.94 in) width

Product Details

HIOKI 2104 Meter Relay is an industrial 1-channel devices to assist in energy saving and automation implementations. The 2104 series are 1-channel ±1.5% class meter relays featuring a sensitive 1 µA, 10 mV DC movement and a customizable scale.

Key Features
• Ultra sensitive 1 µA, 10 mV DC movement
• Includes a display lamp to illuminate movement at a glance
• Relay action delays circuit closure upon power on
• Both power circuitry and relay built-in
*H-type: Lamp lights up and output relay contact operates at deflection of the needle to the right of the setting needle
*L-type: Lamp lights up and output relay contact operates at deflection of the needle to the left of the setting needle
*HL-type: Provides functionality of both H- and L-type models

Basic Specifications
Indicator shape : f 0.3 mm (0.01 in) pin

Accuracy class : [2103H/L/HL]: 2.5 %, [2104H/L/HL]: 1.5 %

Setting accuracy : Within 1.5 % of the full scale value (Independent of meter section)

Dead-zone width : Within 0.5 % of the scale length

Indicator operating range : Within the scale (passing indicator needle system)

Setting indicator (shape and color) : Spear shape
H indicator (upper-limit side): Red, L indicator (lower-limit side): Green

Setting indicator setting range : Within the all range of scale for both H and L

Minimum H/L space : Within 3 % of the scale length

Delay time from power on : Approx. 2 s

Relay contact structure : One transfer for both H and L

Relay output response : Approx. 0.5 s (time constant)

Max. current of relay contact : 5 A (Under condition of 250 V AC, 30 V DC, resistance load)

Power supply : 100 V AC ±10 % (110 / 120 / 200 / 220 / 230 / 240 V, specify at order), 3 VA max.

Product Description

HIOKI 2104 Meter Relay in ±1.5% Class with 1 µA, 10 mV DC Movement for Power Saving Measures and Automation.Setting accuracy is within 1.5 % of the full scale value (Independent of meter section).Maximum current of relay contact is 5 A (Under condition of 250 V AC, 30 V DC, resistance load.

ISKRA 07039.00 Educational Programme The 07039.00 is designed for measuring small DC currents. The instrument is quite suitable for experiments in which the zero method is used, for examp...
ISKRA 07036.00 Educational Programme The 07036.00 is designed for measuring AC/DC currents. Together with our 07035.00 (link at 07036.00) voltmeter, it is adequate for basic and advanced ...
ISKRA 07021.01 Educational Programme The 07021.01 is designed for measuring AC/DC currents and voltages; adequate for technical instruction but also for measuring at electro-technical equ...
ISKRA 07035.00 Educational Programme The 07035.00 is designed for measuring AC/DC voltages. With our ammeter 07036.00 (link at 07036.00) it makes a voltmeter set, suitable for basic and a...
ISKRA MI 7056 Portable Multimeter The MI 7056 portable meter is intended, due to electric and construction features, for a wide range of users. It is provided with rubber border which inc...