Free Call Australia : 1 800 834 991

Related Products

Fluke 1630 Earth Ground Clamp Meter

FLUKE 1630 Earth Ground Clamp Meter 
  • A wide ground loop resistance range, from 0.025 O to1500 O, to satisfy all requirements
  • Time saving memory function automatically records and stores measured values
  • Handy ‘display hold’ button for capturing readings in hard-to-reach places

Product Details

FLUKE 1630 Earth Ground Clamp Meter

Earth Ground loop resistance measurements for commercial, industrial, and utility applications The clamp-on ground testing technique used by the Fluke 1630 simplifies ground loop testing and enables non-intrusive leakage current measurement. The compact and rugged design makes the Fluke 1630 easy to use in small places and harsh environments, while the ‘display hold’ and the continuity testing with an audible alarm function ensures convenience in use. The novel technique means that earth ground loop testing and continuity testing can be completed without breaking the circuit. Stakeless testing system The Fluke 1630 uses the Stakeless testing method, which eliminates the need to disconnect parallel ground rods and find suitable locations for placing auxiliary ground stakes. This saves time and enables users such as industrial and utility electricians, and field service electricians and contractors, to perform earth ground loop tests in locations where it is not possible to use other techniques, including inside buildings or on power pylons. With the Stakeless testing method, earth ground stakes are no longer necessary.

The Fluke 1630 Earth Ground Clamp is placed around the earth ground rod or the connecting cable. A known voltage is induced by one half of the clamp and the current is measured by the other half. The tester automatically determines the ground loop resistance at this grounding connection. A wide ground loop resistance range, from 0.025 O to1500 O, to satisfy all requirements Large jaw opening of 35 mm (1.38 in) for tests on ground conductors and/or equipotential bus bars.

Measurement of ground leakage current, from 0.2 mA to 1000 mA, without needing to disconnect - ideal for system troubleshooting. Wide ac current measurement range from 0.2 A to 30 A allows one instrument for multiple applications. User-defined HI / LO Alarm limits, for rapid measurement evaluation. Handy ‘display hold’ button for capturing readings in hard-to-reach places. Time saving memory function automatically records and stores measured values. Automatic self calibration ensures correct measurement every time. Overload protection: 200 A. Carrying case and resistance test loop included. = 8 hours battery life (continuous operation).

MEGGER DET4T2 Series 4-Terminal Earth/Ground Resistance Testers & Soil Resistivity Testers 2, 3 and 4 point testing. Stakeless (clamp-on) testing capability. ART (Attached Rod Technique) ...
MEGGER C/N 250260 - 3 Terminal Ground Resistance Tester Simple to operate. For quick, routine single-electrode tests. Direct readout in ohms The Three-Terminal Ground Resistance Tester...
MEGGER DET20C Clamp-On Earth Resistance Tester Easy, fast clamp-on operation – No rods or cables necessary. Measures ground resistance from 0.025O to 1550O. Measures ground leakage curren...
HIOKI FT6381 Clamp On Earth Tester measure grounding resistance simply by clamping to multiple-grounded ground wires. No auxiliary grounding rod is needed, and there is no need to disconnect...
MEGGER DET20C Clamp-On Earth Resistance Tester Easy, fast clamp-on operation – No rods or cables necessary. Measures ground resistance from 0.025O to 1550O. Measures ground leakage curren...